Troubleshooting CM6300
Alarm LED Diagnostics
When the alarm is triggered the LED on the RPS (if installed), Secure Valet (if installed) and the LED (if in-
stalled) will flash a certain amount of times as shown in the table below. This is intended for users with 1
Way remotes.
Priority Trigger LED Flash Diagnostic
1 Door/Hood/Trunk/Ign Triggered 2 flashes, break, then repeat
2 2nd Shock Triggered 3 flashes, break, then repeat
3 2nd Auxiliary Input Triggered 4 flashes, break, then repeat
4 Panic with remote 5 flashes, break, then repeat
I have everything hooked up and the system will not respond.
A: The remotes need to be programmed. Review the “Common Procedure” section of this manual.
I am trying to program the control module with the OP500 Option Programmer and it flashes
“ER 01” when I plug it in to the antenna cable. What should I do?
A: Make sure that the system is not locked/armed. The last thing to check is the antenna cable or antenna
extension cable – make sure this is not damaged. If you need to, try another cable. When the OP500
is working properly, it will read “success good.” You no longer need to program the remotes before the
OP500 will sync.
I need a ground when armed wire, does the control module have one?
A: You can use the ground when armed wire on CN3 that goes to the starter kill relay. You must cut this wire
and place a diode in line so that when the ignition on the other side of the relay goes to ground, it won’t
back feed to your accessory. Install the stripe side of the diode facing the control module.
On the brain, how do I set the auxiliaries?
A: Auxiliary 1 through 5 are defaulted on with the CM6300. Although you must have an Option
Programmer (OP500) to change the outputs to a specific time. Secure auxiliary (option 4-05) will
prevent these outputs from triggering without doing query first. Please review the “Special Option Group
programming section of this manual for more details.
The vehicle will lock and unlock but not flash the parking lights.
A: The system is in valet mode. Tap buttons (I) + (III) for 0.5 second or Lock and Trunk Release buttons for a
half second.