1-04 Double Pulse Unlock - If enabled, this option will cause the system to double pulse the lock, unlock
or both lock and unlock outputs. This can be used for vehicles that need two pulses to unlock or
relock the doors.
1-07 Unlock / Disarm with Trunk Release - This option sets what the unlock and/or factory disarm wires do
during remote trunk release.
1-08 Locking while in Passive Arming - This feature controls what the lock wire does during passive mode
1-09 Ignition Controlled Locks - Setting 2 will lock the doors when the ignition is turned on and doors
closed. Tach sensing mode must be used for setting 3. You must also turn this feature on
through the remote by tapping I+IV (2 Way remotes) or Lock+Key (1 Way remotes).
1-10 Auto Relock – This option will automatically relock/rearm after the system has been disarmed and
the doors have not been opened within the selected period of time.
1-11 Ignition / Accessory Upon Unlock (Negative Out) – This option will pulse the ignition wire, accessory,
or both upon unlock/disarm. Most new Chrysler vehicles need the ignition and accessory pulsed to
disarm the factory alarm.
1-13 Double pulse disarm - This feature changes the behavior of the small orange/white disarm wire.
When the feature is turned on it will change the default single pulse to double pulse upon disarm/
unlock.
1-14 Auto Mode - This option turns the auto lock/arm and unlock/disarm feature on. This is only
available with international 2 Way remotes. The user must also turn this feature on with the remote
by holding button1 for 2.5 seconds. This mode will automatically lock/arm and unlock/disarm when
the user leaves or enter the range of the vehicle. Setting 3 will enable the FT-EZGO functionality.
1-15 Trunk Output Timing - This option changes the time of the output pulse on the violet/white wire
during trunk release. The default setting is 1 second. With the options you can extend the
output by 2, 3 or 4 seconds to a maximum of 4 seconds.
CM6300 Install Guide
Alarm System
www.firstechonline.com | www.compustar.com
3-03 Dome Light Delay – This option is used when connecting the door trigger input to the vehicles dome
light circuit. It delays the door trigger input to prevent the door open icon displaying on 2 Way