3-15 Soft Disarm - When a vehicle has a factory alarm, and the Firstech alarm is triggered, you may have
both alarms triggered at the same time. In the default setting, silencing the Firstech system will not
send the disarm pulse to the factory system, therefore requiring the user to first silence the Firstech
system and then unlock and disarm to silence the factory system. Setting II sends the disarm and 5
seconds later sends the rearm pulse.
3-16 RPS - This option changes the between the option RPS 2 or the new RPS Touch. Please see the
Placement and Use of Components section of this manual for details.
4-01 Aux 1 Output - This option determines the duration of the auxiliary 1 output. Setting IV allows the
output duration to be set for a specific length of time.
4-02 Aux 2 Output - This option determines the duration of the auxiliary 2 output. Setting IV allows the
output duration to be set for a specific length of time.
4-03 Aux 1 Output Control - This option controls the way auxiliary 1 is controlled at different events.
4-04 Aux 2 Output Control - This option controls the way auxiliary 2 is controlled at different events.
4-05 Secure Aux Output – On the default setting, button 4 on the remote must be pressed first before Aux
1 or Aux 2 can be triggered. This prevents accidental triggering of the outputs. Option setting II turns
this feature off.
4-06 Aux 1 Input – This option changes the input behavior of the pre-warn wire on the Aux Input Sensor
green connector.
Default 1: Will pre-warn with a negative (-) ground input.
Option 2: Will instant trigger with a negative (-) ground input.
Option 3: Will disarm the alarm with a negative (-) ground input. Used when adding an alarm to a
factory keyless entry system.
Option 4: Changes the output into an open circuit input.
CM6300 Install Guide